3,68

Disponibile

1 - 9 3,68
10 - 19 3,43
20 - 29 2,70
30 - 39 2,21
40+ 1,96
,

Descrizione

Download Data Sheet C1

 

C Series thermal protectors are highly efficient miniaturized bimetal switches made to protect electrical equipment (electric motors, transformers, electronic boards, etc.) against abnormal temperature rises. The C Series (C1, C4, C8), due to the combination of the materials used for the contacts with the type of bimetal chosen, is suitable for any application where temperature control is needed.

The bimetallic disk used for models C1 and C8 is sensitive to current overloads and reacts extremely quickly, while model C4 has low current sensitivity.

MAGNETIC AND MECHANICAL PROTECTION  The C Series housing is constructed of steel-nickel to ensure resistance to mechanical pressure over 600 N. The housing also allows the thermostat to be insensitive to magnetic fields, this prevents spark deflection.

TERMINALS  Terminals, whose dimensions (section and length) do not directly affect those of the thermostat, are placed on the front side to prevent damage during head forming.Terminals can be supplied to customer specifications.

CONSTANT CONTACT RESISTANCE  The strength of the contacts is ensured by the selection of materials used and the high clamping pressure.The behavior of the C series is consistent over time.

IMMEDIACY OF SHUT-DOWN  Switching times are particularly short as a function of the high sensitivity of the bimetal.

CAVETTI  Cables are supplied according to customer specification.

PATENTED DESIGN

AUTOMATIC PRODUCTION  Thermostat production is fully automated and is inspected at 100%.

HOMOLOGATIONS  C series thermostats are VDE, UL and CQC approved

THERMAL RESPONSE  The thermal characteristics of the C-series are further accentuated by the type of current-sensitive bimetal that is used to provide even greater protection against current surges.

PIN VERSIONS.  For electronic board applications, the protectors are made with a metal housing covered with a plastic film, and PIN terminals are used for the electrical connection.

To learn more, click on the links to our articles:

WHAT CAUSES CONTACTS TO OPEN AND CLOSE IN A BIMETALLIC DEVICE
THERMAL PROTECTORS AND JOULE EFFECT
THE COMPRESSIVE STRENGTH
THE TOLERANCE ON TEMPERATURE
THE SENSITIVE SIDE OF THE PROTECTOR
RESET AND ROOM TEMPERATURE
OPENING AND CLOSING CONTACTS OR ON/OFF?
CYCLES: THE LIFE OF A THERMOSTAT
BATCH OF PRODUCTION
TENSILE STRENGTH
IS THERE A FIXATION FOR THERMAL PROTECTORS?
CLIP FASTENING OR SCREW FASTENING?
THE ENGINES AND THE PAINT
THE DOWNGRADE IN DETAIL
THERMAL PROTECTORS WITH DUAL PROTECTION